Guangzhou Huilin Air Separation Equipment Co., Ltd.
Main products:Nitrogen Generator,Oxygen Generator
Products
Contact Us
  • Contact Person : Ms. Mary
  • Company Name : Guangzhou Huilin Air Separation Equipment Co., Ltd.
  • Tel : 86-20-61933921
  • Fax : 86-20-61933922
  • Address : Guangdong,Guangzhou,B3-2 Nancun Hi-tech Industrial Park,Panyu District
  • Country/Region : China
  • Zip : 511442

Hospital PSA Oxygen generation systems with compressed Oxygen output

Hospital PSA Oxygen generation systems with compressed Oxygen output
Product Detailed
Brand Name: Huilin ; Usage: metal treatment ; O2 Output:: 50~360Nm3/h

1 Specification of the equipment

Selections

Specifications

Remarks

WG-STDO-110

Item No.

WG-STDO-110

——

O2 Flow

110Nm3/hour

——

O2 Purity

93±2%

——

Export Pressure of O2

150Bar

Adjustable

O2 Dew Point

-45°C

Atmospheric

Compressed Air Consumption

1320 Nm3/hour

6Bar

Mode of operation

Full automatic

——

Specification of key machine

1 Air Compressor

Item

Atlas Copco Screw Air Compressor

 

Item

GA-132

Air Output

≥24Nm3/min

Export Pressure

≥0.7Mpa

Function

Provide compressed air.

O2/N2 Separation System

Item

Specifications

Notes

 

Item

WG-STDO-110

HUILIN

O2 Flow

110Nm3/h

Standard

Compressed Air Consumption

1320Nm3/hour

Standard

O2 Purity

93±2%

--------

Output Pressure

4Bar

Can be adjustment

O2 Dew Point

-45°C

Atmospheric

Running Time

≥8600h/year

Continuous Work

Equipment Life

20 years

zeolite molecular sieve for 10 years.

3Air Compressor

Item

Oxygen Compressor

 

Type

VW-2/41-150

Oxygen Output

≥110Nm3/hour

Export Pressure

≥150Bar

Function

Provide compressed Oxygen

The Component Description

This PSA Oxygen Generator is composed of Air Compressed System, Air Purification System, Air Tank System, O2/N2 Separation System, Oxygen Buffer System, Oxygen Compressed System and Electrical Control System.

1 Air Compressed System

                                                                                                      

Air Compressed System can compress the air to desired pressure of 7 bar or more..

2 Air Purification System

Air Purification System used to remove dust, water and oil from compressed air. It’s mainly composed of three sets of filters, freezing drier and effective oil removal.

3 Air Tank System

The Air Tank Systems can avoid the gas transmission of O2/N2 to separation system at too rapid flow velocity, So it can improve purification of air and expand the working life of carbon molecular sieve. Air Tank System is composed of air tank, safety valve, closing valves, ball valves, and pressure gauges ect.

4 O2/N2 Separation System

The O2/N2 Separation System utilizes two towers which are filled with zeolite molecular sieve. Compressed air enters the bottom of the "online" tower and flows up through the zeolite molecular sieve, N2, CO2 and H2O gases are preferentially adsorbed by the zeolite molecular sieve, allowing Oxygen to pass through. After a pre-set time the on-line tower automatically switches to the regenerative mode, venting contaminants from the the zeolite molecular sieve. When one tower produces O2, another tower releases the N2, CO2 and H2O at the same time. Two towers alternate adsorption and regeneration to output O2 continuously.

5 Oxygen Buffer System        

The main role of oxygen gas buffer system is to balance the pressure and purity of oxygen gas which separated from O2/N2 separation system to ensure continuous supply of oxygen gas. Oxygen gas buffer system is composed of buffer tank, flowmeters, dust filters, pressure regulating valve, throttle, and safety valve etc.

6 Oxygen Compressed System

The Oxygen Compressed System can compress the Oxygen to desired pressure of 150bar or more.

7 Electrical Control System

Electrical Control System is to control start-up & shutdown operation, the status light, sound and light alarm fault instructions, purity display, driving pneumatic valve by setting procedures etc. Electrical Control System is composed of the process controller CPU, triple gas source, electromagnetic valves, lights etc

8 Bacteria killing System

The Bacteria killing System can kill Bacteria in the Oxygen

Characteristics of HUILIN PSA Oxygen Gas Generator

  

Convenient to install :

More economic than other oxygen supplying methods

The macaronis design realizes the automatic running

  

Peak value / the security system of the trouble

  

The high-quality components and parts are the reliable assurance of steady operation

     

 Oxygen content shows in succession, equipping the transfinite automatic alarm system:

  

The high-quality zeolite molecular sieve:

The advanced loading technology guarantees the service life of equipments

The automatic alarm system for sinking of the carbon molecule sieve:

   

The unqualified oxygen automatic emptying system

Differential pressure indication, concentrating blow down system:

  

The unique inter-circle switching techniques’ of system

.

Hospital PSA Oxygen generation systems with compressed Oxygen output



Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.